| No. |
Item |
Requirements |
Test Method |
| 1 |
Discharge rate
performance |
Discharge
Capacity/Nominal
capacity×100%
0.3C5≥100%
1.5C5A ≥90% |
a).Standard charge at 0.3C5A under the condition of normal atmospheric pressure and the environmental
temperature of 20℃±5℃ and 45%~80% RH,discharge at 1I3/4.5I3(A) to 2.0V or the cut-off voltage which is specified in the technical document of the company.
b)the capacity(AH)=the discharge time*discharge current, and then is described the percentage of the nominal capacity
(Charge/discharge cycle can be conducted for 3 times before meeting the Standards(the same below). |
| 2 |
High-low
Temperature
Discharge
performance |
Discharge
Capacity/Nominal
capacity×100%
A) 55℃≥95%;
B) -20 ℃≥55%; |
A. After Standard charging. Then store it at the constant temperature of 55±2℃ for 5h(of -20±2℃ for 20h), and discharge at 0.3C5A to 2.0V or the cut-off voltage which is specified in the technical document of the company, the capacity(AH)=the discharge time*discharge current, and then is described the percentage of the nominal capacity. |
| 3 |
Normal Storage/
High
Temperature
Storage |
Residual Capacity
≥Nominal
capacity*80%
Recoverable
capacity≥Nominal
capacity *90% |
Store for 28 days(Store for 7 days at the constant temperature of 55±2℃) after standard charge, then measure final status and residual capacity at 0.3 C5A to 2.0V or the cut-off voltage which is specified in the technical document of the company; After charge/discharge(0.3C5A /0.3C5A) cycle can be conducted for 3 times , recoverable capacity will be tested |
| 4 |
storage
performance |
recoverable capacity
≥ nominal capacity
*95% |
Standard charge and then rest for 1H,then discharge for 2H at 0.3C5A, storge for 90 days
at 20℃±5℃,After standard charge, then discharge at 0.3C5A, (Charge/discharge cycle can
be conducted for 5 times before meeting the Standards(the same below) |
| 5 |
Cycle Life |
Discharge Capacity
≥Nominal
capacity*80% |
conduct 0.3C5A/0.3C5A cycle for 2000 times .The discharge
capacity shall be measured after 2000 cycles. |